It is possible that updates have been made to the original version after this document was translated and published. please RamNagalla Moderator Partner Trusted Advisor Certified ‎07-29-2013 12:33 PM Options Mark as New Bookmark Subscribe Subscribe to RSS Feed Highlight Print Email to a Friend Report Inappropriate Content agreed with Example : folder bpbrm for bpbrm logs and enable logging on master host properties and for client you can do it from BAR window from client side. Abby 0 Kudos Reply hi Rajeev, 1. weblink

you can make a connection RamNagalla Moderator Partner Trusted Advisor Certified ‎07-26-2013 10:38 AM Options Mark as New Bookmark Subscribe Subscribe to RSS Feed Highlight Print Email to a Friend Report Step 5: Ensure the client server has the bpcd and vnetd port in listening mode using the command netstat -a: On Windows:    TCP    dotto:vnetd       dotto.veritas.com:0  LISTENING TCP    dotto:bpcd        dotto.veritas.com:0  LISTENING   Ensure that master can resolve client's IP address to the Client name contained in the policy. Is there any commmand we can use or any GUI method to get confirmed as Ports are blocked ?

Cannot Connect On Socket Netbackup

Thank You! Hostname lookup: Use 'bpclntcmd -hn ' and 'bpclntcmd ip

e.g. No Yes How can we make this article more helpful? Drive type: Open the NetBackup administration consoleExpand Media and Device ManagementSelect Devices.  The right column indicates the device topology in the upper view, and the lower view lists all drives.The Device Netbackup Cannot Connect To Client 58 Step 2: In 6.x and above environments you can use the command- bptestbpcd to verify you can connect to both the vnetd and bpcd ports on the client server.

No Yes Menu Close Search SOLUTIONS Solutions Overview Unstructured Data Growth Multi-Vendor Hybrid Cloud Healthcare Government PRODUCTS Product Overview Backup and Recovery Business Continuity Storage Management Information Governance Products A-Z SERVICES Backup completed . 0 Kudos Reply Mounting the databases on Marianne Moderator Partner Trusted Advisor Accredited Certified ‎08-04-2014 12:41 PM Options Mark as New Bookmark Subscribe Subscribe to RSS Feed Highlight Is "telnet " the only way by which we can be sure about Port is not open. 0 Kudos Reply i believe.. Check bprd log on the master for request from client's IP address.

You may also refer to the English Version of this knowledge base article for up-to-date information. Bptestbpcd Main: Function Connecttobpcd Failed: 25 No Yes How can we make this article more helpful? No Yes How can we make this article more helpful? The bpcd log shows status 98.The bptm log lists a message: mount_open_media: error requesting media, TpErrno = Requested number of drives are not configured.These error messages indicate a mismatch between the

Netbackup Cannot Connect On Socket Linux

Can you ping the server? Close Sign In Print Article Products Article Languages Subscribe to this Article Manage your Subscriptions Problem Error : "Cannot connect to socket (25)"Backup fails with Status code 58: Can't connect Cannot Connect On Socket Netbackup Showing results for  Search instead for  Do you mean  VOX : Backup and Recovery : NetBackup : can't connect on socket VOX : Backup and Recovery : NetBackup : can't connect Netbackup Cannot Connect On Socket 25 Windows Sorry, we couldn't post your feedback right now, please try again later.

Error Message Exit Status 25 - cannot connect on socket. http://bovbjerg.net/cannot-connect/veritas-server-status-cannot-connect-on-socket.php Sorry, we couldn't post your feedback right now, please try again later. telnet is may be RamNagalla Moderator Partner Trusted Advisor Certified ‎07-31-2013 08:50 AM Options Mark as New Bookmark Subscribe Subscribe to RSS Feed Highlight Print Email to a Friend Report Inappropriate Step 6: Locally on the client create a bpcd log and increase the verbose level to 5. Bppllist Cannot Connect On Socket 25

All i did is the normal procedures that i do to all my other servers but this one is not able to connect. Not sure of your NB version but the following probably cover the same things:............I have a 6.5.3 Master Server Console. If NBU server and clients are on the same internal network and protected from external threats by the Company firewall, there is actually no need for individual firewalls. check over here Check what services the client is running for Windows clients (Try Turning off MS firewall software for a quick test) or check the hosts.allow and hosts.deny files on the UNIX clients

Email Address (Optional) Your feedback has been submitted successfully! Bptestbpcd Cannot Connect On Socket Thank You! It is possible that updates have been made to the original version after this document was translated and published.

add the ports in excepstion list and check the comminication.. 0 Kudos Reply Why we have to Disable it Marianne Moderator Partner Trusted Advisor Accredited Certified ‎07-26-2013 10:42 AM Options Mark

  • Please create bpcd log folder on the client under /usr/openv/netbackup/logs Run bptestbpcd again on master: bptestbpcd -client -debug -verbose http://www.symantec.com/docs/HOWTO43696 5.
  • If it does not exist, create the folder and restart NBU.
  • Article:000008360 Publish: Article URL:http://www.veritas.com/docs/000008360 Support / Article Sign In Remember me Forgot Password? Don't have a Veritas Account? Create a Veritas Account now! Welcome First Last Your Profile Logout Sign in
  • Email Address (Optional) Your feedback has been submitted successfully!
  • Cause Examine the bpcd log from the client for evidence of the following 10:44:50.087 [9501] <2> bpcd main: setup_sockopts complete10:44:50.091 [9501] <8> bpcd peer_hostname: gethostbyaddr failed : HOST_NOT_FOUND (1)10:44:50.091 [9501] <16>
  • Close Sign In Print Article Products Related Articles Article Languages Subscribe to this Article Manage your Subscriptions Problem Status Code 25: "Cannot connect on socket" occurs during restore Error Message
  • Veritas does not guarantee the accuracy regarding the completeness of the translation.

Is anything logged in bpcd? set loging level to 5 to get complete details since your saying ping telnet and host resolution is fine, if this is the newclient that is having problem try restarting NB Is the NB client running on the new client? Netbackup Bpclntcmd Thanks for providing the Marianne Moderator Partner Trusted Advisor Accredited Certified ‎01-06-2015 01:01 AM Options Mark as New Bookmark Subscribe Subscribe to RSS Feed Highlight Print Email to a Friend Report

status: 58: can't connect to client Labels: 7.6 Agent for Microsoft Exchange Server Backup and Recovery NetBackup Windows Server (2003-2008) 1 Kudo Reply 6 Replies Check if the reboot maybe Marianne No Yes Veritas.com Support Veritas Open Exchange Login or Join Communities Information Governance Backup and Recovery Business Continuity Partners Inside Veritas Vision 2016 Developers Blogs Groups Vision 2016 Veritas.com Support Communities I am able to telnet the port 13782 Can you guys tell me how to enable logs in windows for bpbrm,bptm,bprd,bpdbm,bpcompatd and bpjobd. this content bpclntcmd -clear_host_cache Thanks 0 Kudos Reply Hi All Thanks for the Igselva Level 3 ‎07-21-2014 06:43 AM Options Mark as New Bookmark Subscribe Subscribe to RSS Feed Highlight Print Email

No Yes Menu Close Search SOLUTIONS Solutions Overview Unstructured Data Growth Multi-Vendor Hybrid Cloud Healthcare Government PRODUCTS Product Overview Backup and Recovery Business Continuity Storage Management Information Governance Products A-Z SERVICES You may also refer to the English Version of this knowledge base article for up-to-date information. Terms of use for this information are found in Legal Notices.

Related Articles Article Languages x Translated Content Please note that this document is a translation from English, and may This way you can verify how Netbackup sees the servers based on the hostnames and IP addresses] To test the master/media server resolution of the client server hostname run the following

On the client server to test whether the bpcd binary is executable and will generate a log issue the following command: UNIX: netbackup/bin/bpcd Windows program files\VERITAS\netbackup\bin\bpcd This will generate Article:000007335 Publish: Article URL:http://www.veritas.com/docs/000007335 Support / Article Sign In Remember me Forgot Password? Don't have a Veritas Account? Create a Veritas Account now! Welcome First Last Your Profile Logout Sign in Coz this is really strange problem i never faced before.